Alternative Approach to Optical Detection of Partial Discharges in Air

التفاصيل البيبلوغرافية
العنوان: Alternative Approach to Optical Detection of Partial Discharges in Air
المؤلفون: Šefl, Ondřej, Procházka, Radek, Haller, Rainer, Monkman, G. J.
المصدر: 2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP).
بيانات النشر: IEEE, 2021.
سنة النشر: 2021
مصطلحات موضوعية: insulation, surface discharges, sensor phenomena and characterization, discharges, partial discharges, UHF antennas, electrodes
الوصف: This article compares the standard electrical method of partial discharge detection with a novel optical detection method based on silicon photomultipliers. A third, complementary, single-loop antenna method is added to represent the ultra-high frequency method commonly used in gas-insulated switchgear/lines. A trio of air-insulated electrode designs that simulate the fundamental fault/discharge types in gaseous insulation (protrusion - corona discharge, floating conductive particle, surface discharges) are employed. Phase-resolved partial discharge activity patterns are compiled for each electrode design. The patterns are analyzed using spatial statistics and the interpretation of the obtained data trends explained by means of an example. Ultimately, the consistency and reliability of discharge detection by the optical methods for each fault/discharge type are evaluated, and suggestions for improvement are made. This article compares the standard electrical method of partial discharge detection with a novel optical detection method based on silicon photomultipliers. A third, complementary, single-loop antenna method is added to represent the ultra-high frequency method commonly used in gas-insulated switchgear/lines. A trio of air-insulated electrode designs that simulate the fundamental fault/discharge types in gaseous insulation (protrusion - corona discharge, floating conductive particle, surface discharges) are employed. Phase-resolved partial discharge activity patterns are compiled for each electrode design. The patterns are analyzed using spatial statistics and the interpretation of the obtained data trends explained by means of an example. Ultimately, the consistency and reliability of discharge detection by the optical methods for each fault/discharge type are evaluated, and suggestions for improvement are made.
وصف الملف: application/pdf
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::55ef39f028ad13a1574cf854d21fcde1Test
https://doi.org/10.1109/ceidp50766.2021.9705350Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....55ef39f028ad13a1574cf854d21fcde1
قاعدة البيانات: OpenAIRE