DEVELOPMENT AND VALIDATION OF A GAIT CLASSIFICATION SYSTEM FOR OLDER ADULTS BY MOVEMENT CONTROL AND BIOMECHANICAL FACTORS

التفاصيل البيبلوغرافية
العنوان: DEVELOPMENT AND VALIDATION OF A GAIT CLASSIFICATION SYSTEM FOR OLDER ADULTS BY MOVEMENT CONTROL AND BIOMECHANICAL FACTORS
المؤلفون: Huang, Wen-Ni Wennie
مرشدي الرسالة: Jessie VanSwearingen, Stephanie Studenski, Jennifer Brach, Subashan Perera
بيانات النشر: University of Pittsburgh, 2006.
سنة النشر: 2006
المجموعة: University of Pittsburgh
Original Material: http://etd.library.pitt.edu/ETD/available/etd-08082006-172300Test/
مصطلحات موضوعية: Rehabilitation Science
الوصف: Purpose: The purpose of this study was to establish reliability and validity of a clinically useful gait classification system for older adults using gait and physical performance measures in 2 different populations. Methods: We classified gait patterns using structured clinical observation and expected the gait patterns to be defined by variability of movement (consistent, inconsistent) and postural biomechanical factors (usual, flexed, extended, crouched) observed in walking. Male veterans (n=106) referred to the VA GEM Program (mean age, 76; SD, 7.1; range, 63-97 years) were videotaped for analyses. The inter- and intra-rater reliability was determined. Pair-wise comparisons across various groups were performed to validate the gait classification using gait parameters (gait speed, step length, width and variability), lower extremity range of motion and muscle strength, physical function in ADL (Physical Performance Test, PPT) and gait abnormalities (GARS-M). The validity of the gait classification system was further validated in a different population consisting of 34 community-dwelling older adults (mean age, 84; SD, 5.0; range, 70-91 years). Results: Kappas for interrater reliability of the variability and postural components of the gait classification system were 0.59 and 0.75, respectively; for intrarater reliability, 0.82 and 0.72, respectively. Consistent and inconsistent groups were different in gait speed (0.66 and 0.49m/s, respectively; p=0.003), step length (0.46 and 0.38m; p=0.008), step length variability (7.47% and 12.74%; p=0.043), the PPT (15.80 and 11.73; p
Original Identifier: oai:PITTETD:etd-08082006-172300
نوع الوثيقة: text
وصف الملف: application/pdf
اللغة: English
الإتاحة: http://etd.library.pitt.edu/ETD/available/etd-08082006-172300Test/
حقوق: unrestricted
I hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to University of Pittsburgh or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.
رقم الانضمام: edsndl.PITT.oai.PITTETD.etd.08082006.172300
قاعدة البيانات: Networked Digital Library of Theses & Dissertations