دورية أكاديمية

Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?

التفاصيل البيبلوغرافية
العنوان: Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?
المؤلفون: Chkili, Sophia, Lefebvre, Yolène, Chao, Shih-Li, Bali, Maria Antonietta, Lemort, Marc, Coquelet, Nicolas
المصدر: Neuroradiology; Jul2023, Vol. 65 Issue 7, p1133-1141, 9p
مصطلحات موضوعية: DIGITAL image processing, STATISTICS, THREE-dimensional imaging, METASTASIS, MAGNETIC resonance imaging, CONTRAST media, RETROSPECTIVE studies, BRAIN tumors, DIAGNOSTIC imaging, COMPARATIVE studies, DESCRIPTIVE statistics, DIAGNOSTIC errors, SENSITIVITY & specificity (Statistics), DATA analysis, RESEARCH bias, NEURORADIOLOGY, DRUG administration, DRUG dosage
مستخلص: Purpose: Sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE). Our study aims to (i) evaluate the diagnostic accuracy of SPACE compared to its use in combination with VIBE, (ii) investigate the effect of radiologist's experience in the sequence's performance, and (iii) analyze causes of discordants results. Methods: Four hundred seventy-three 3T MRI scans were retrospectively analyzed following a monocentric study design. Two studies were formed: one including SPACE alone and one combining both sequences (SPACE + VIBE, the reference). An experienced neuroradiologist and a radiology trainee independently reviewed the images of each study and reported the number of brain metastases. The sensitivity (Se) and specificity (Sp) of SPACE compared to SPACE + VIBE in metastases detection were reported. Diagnostic accuracy of SPACE compared to SPACE + VIBE was assessed by using McNemar's test. Significance was set at p < 0.05. Cohen's kappa was used for inter-method and inter-observer variability. Results: No significant difference was found between the two methods, with SPACE having a Se > 93% and a Sp > 87%. No effect of readers' experience was disclosed. Conclusion: Independently of radiologist's experience, SPACE alone is robust enough to replace SPACE + VIBE for brain metastases detection. [ABSTRACT FROM AUTHOR]
Copyright of Neuroradiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00283940
DOI:10.1007/s00234-023-03143-8