دورية أكاديمية

First clinical use of a bioprosthetic total artificial heart: report of two cases.

التفاصيل البيبلوغرافية
العنوان: First clinical use of a bioprosthetic total artificial heart: report of two cases.
المؤلفون: Carpentier, Alain1 alain.carpentier@egp.aphp.fr, Latrémouille, Christian1, Cholley, Bernard2, Smadja, David M.3, Roussel, Jean-Christian4, Boissier, Elodie4, Trochu, Jean-Noël4, Gueffet, Jean-Pierre4, Treillot, Michèle4, Bizouarn, Philippe4, Méléard, Denis2, Boughenou, Marie-Fazia2, Ponzio, Olivier1, Grimmé, Marc5, Capel, Antoine5, Jansen, Piet5, Hagège, Albert6, Desnos, Michel6, Fabiani, Jean-Noël1, Duveau, Daniel4
المصدر: Lancet. 10/17/2015, Vol. 386 Issue 10003, p1556-1563. 8p. 2 Color Photographs, 1 Diagram, 2 Graphs.
مصطلحات موضوعية: *PILOT projects, BIOPROSTHESIS, HEART transplantation, TREATMENT effectiveness, DILATED cardiomyopathy, DISEASE complications, ARTIFICIAL hearts
مستخلص: Background: The development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant.Methods: The C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France.Findings: The C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2 experienced a transient period of renal failure and a pericardial effusion requiring drainage, but otherwise uneventful postoperative course. He was discharged from the hospital on day 150 after surgery with a wearable system without technical assistance. After 4 months at home, the patient suffered low cardiac output. A change of C-TAH was attempted but the patient died of multiorgan failure.Interpretation: This preliminary experience could represent an important contribution to the development of total artificial hearts using bioprosthetic materials.Funding: CARMAT SA. [ABSTRACT FROM AUTHOR]
Copyright of Lancet is the property of Lancet and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Business Source Index
الوصف
تدمد:01406736
DOI:10.1016/S0140-6736(15)60511-6