دورية أكاديمية

Realistic and Efficient Modeling of Radiotracer Heterogeneity in Monte Carlo Simulations of PET Images With Tumors.

التفاصيل البيبلوغرافية
العنوان: Realistic and Efficient Modeling of Radiotracer Heterogeneity in Monte Carlo Simulations of PET Images With Tumors.
المؤلفون: Stute, Simon1, Vauclin, Sébastien2, Necib, Hatem1, Grotus, Nicolas1, Tylski, Perrine1, Rehfeld, Niklas S.1, Hapdey, Sébastien2, Buvat, Irène1
المصدر: IEEE Transactions on Nuclear Science. 2/1/2012 Part 1 Part 1, Vol. 59 Issue 1, p113-122. 10p.
مصطلحات موضوعية: *MONTE Carlo method, RADIOACTIVE tracers, IMAGING phantoms, POSITRON emission tomography, PATIENT monitoring, SINGLE-photon emission computed tomography
مستخلص: Monte Carlo simulations are extensively used in PET to evaluate the accuracy with which PET images can yield reliable estimates of parameters of interest. For such applications, the simulated images should be as realistic as possible so that conclusions can be extrapolated to clinical PET images. In this work, we describe a method for introducing realistic modeling of radiotracer heterogeneity into Monte Carlo simulations of patient PET scans. The modeling of the complex physiological activity distribution in healthy regions is directly based on real patient PET/CT images, and realistic tumor shapes can be included into these regions. This method represents a competitive alternative to the use of complex anthropomorphic phantoms such as the XCAT, that require a fixed activity per structure. The method is extended to the simulation of serial PET scans with tumor changes, as acquired in the context of therapy monitoring, and this extension is validated using a patient study. Using the proposed method, very realistic patient PET images can be produced for evaluation purposes.In addition, a strategy to efficiently simulate many sets of pathological cases, based on a unique background physiological activity distribution, is described and carefully assessed using a numerical phantom. The background activity is simulated only once, while tumors are simulated separately. The data are then recombined in a specific way so that the final image has the same properties as images produced by simulating pathological and tumor activities at the same time. [ABSTRACT FROM PUBLISHER]
Copyright of IEEE Transactions on Nuclear Science is the property of IEEE and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Business Source Index
الوصف
تدمد:00189499
DOI:10.1109/TNS.2011.2177277