المؤلفون: Prajsnar-Borak, Anna, Teping, Fritz, Oertel, Joachim
بيانات النشر: Saarländische Universitäts- und Landesbibliothek
سنة النشر: 2022
المجموعة: SciDok - Der Wissenschaftsserver der UdS (Universität des Saarlandes)
مصطلحات موضوعية: ddc:610, ShuntScope, Pediatric hydrocephalus, Endoscopy, Ventricular catheter, Shunting
الوصف: Purpose Ventricular catheter implantation in pediatric hydrocephalus can become a highly challenging task due to abnormal anatomical confguration or the need for trans-aqueductal stent placement. Transluminal endoscopy with the ShuntScope has been invented to increase the rate of successful catheter placements. This study aims to evaluate ShuntScope’s image qualities and related surgical outcomes in the pediatric population. Methods A retrospective analysis of all pediatric patients undergoing ventricular catheter placement using the ShuntScope from 01/2012 to 01/2022 in the author’s department was performed. Demographic, clinical, and radiological data were evaluated. The visualization quality of the intraoperative endoscopy was stratifed into the categories of excellent, medium, and poor and compared to the postoperative catheter tip placement. Follow-up evaluation included the surgical revision rate due to proximal catheter occlusion. Results A total of 65 ShuntScope-assisted surgeries have been performed on 51 children. The mean age was 5.1 years. The most common underlying pathology was a tumor- or cyst-related hydrocephalus in 51%. Achieved image quality was excellent in 41.5%, medium in 43%, and poor in 15.5%. Ideal catheter placement was achieved in 77%. There were no intraoperative complications and no technique-related morbidity associated with the ShuntScope. The revision rate due to proximal occlusion was 4.61% during a mean follow-up period of 39.7 years. No statistical correlation between image grade and accuracy of catheter position was observed (p-value was 0.290). Conclusion The ShuntScope can be considered a valuable addition to standard surgical tools in treating pediatric hydrocephalus. Even suboptimal visualization contributes to high rates of correct catheter placement and, thereby, to a favorable clinical outcome.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 1433-0350
0256-7040
العلاقة: https://link.springer.com/article/10.1007/s00381-022-05776-1#Sec17Test; http://nbn-resolving.org/urn:nbn:de:bsz:291--ds-387796Test; hdl:20.500.11880/34946; http://dx.doi.org/10.22028/D291-38779Test
DOI: 10.22028/D291-38779
DOI: 10.1007/s00381-022-05776-1
الإتاحة: https://doi.org/10.22028/D291-38779Test
https://doi.org/10.1007/s00381-022-05776-1Test
http://nbn-resolving.org/urn:nbn:de:bsz:291--ds-387796Test
حقوق: openAccess ; Attribution 4.0 International (CC BY 4.0) ; https://creativecommons.org/licenses/by/4.0Test/
رقم الانضمام: edsbas.DDE95653
قاعدة البيانات: BASE
الوصف
تدمد:14330350
02567040
DOI:10.22028/D291-38779