دورية أكاديمية

Mononuclear cell collection for extracorporeal photopheresis by using the “off‐line” system: A comparative study between COBE Spectra and Spectra Optia devices

التفاصيل البيبلوغرافية
العنوان: Mononuclear cell collection for extracorporeal photopheresis by using the “off‐line” system: A comparative study between COBE Spectra and Spectra Optia devices
المؤلفون: Pascual, Cristina, González‐Arias, Elena, Pérez‐Corral, Ana María, Bailén, Rebeca, Gayoso, Jorge, Besson, Nelly, Serrano, David, Kwon, Mi, Anguita, Javier, Díez‐Martín, José Luis
المصدر: Journal of Clinical Apheresis ; volume 34, issue 4, page 359-366 ; ISSN 0733-2459 1098-1101
بيانات النشر: Wiley
سنة النشر: 2018
المجموعة: Wiley Online Library (Open Access Articles via Crossref)
الوصف: Background Extracorporeal photopheresis (ECP) is an efficient and established therapy to treat acute and chronic graft vs host disease (GVHD). Using an “off‐line ” method, the first step (mononuclear cell [MNC] collection) is decisive, as long as a high MNC yield and purity in the collected product is desirable. Two “off‐line ” devices were compared: the COBE Spectra and the Spectra Optia (Terumo BCT), using both continuous and intermittent protocols. Patients and methods Twelve patients with GvHD (7 acute/5 chronic) were enrolled between June 2014 and May 2015 and were alternatively assigned for each procedure to either the COBE Spectra or the Spectra Optia cell separator. Patients characteristics and procedure/product parameters were analyzed. Results Two hundred procedures (100 per device) were included. The Spectra Optia system showed higher total nucleated cells and MNC collection efficiencies (18.6(10.2‐29.7) vs 7.9(4.1‐14.8)% and 43.6(20.3‐59.5) vs 23.3(11.4‐37.1)%, P < .001) and monocyte and lymphocyte collection efficiencies (55.2(17.7‐83.2) vs 22.8(9‐38.9)% and 38.3(26.7‐53.4) vs 22.2(9‐38.9)%, respectively, P < .001). Absolute platelet loss (PL) and PL per liter of blood processed were significantly lower in the Spectra Optia group (22.9(18.3‐28.1) vs 33.6(26.5‐41.1)%, P < .001 and 3.7(3.1‐4.5) vs 4.3(3.5‐4.2)%, P = .01, respectively). However, granulocyte contamination was higher (4.5(1.3‐36) vs 1.2(0.4‐5.7)%, P < .001) and a higher product haematocrit was obtained with the Spectra Optia (1(0.5‐1.6) vs 0.3(0.2‐0.5)%, P < .001), without an impact on irradiation time. Conclusions In our study, Spectra Optia proved to be safe and effective in collecting MNC with high yield and purity for ECP in GvHD.
نوع الوثيقة: article in journal/newspaper
اللغة: English
DOI: 10.1002/jca.21679
الإتاحة: https://doi.org/10.1002/jca.21679Test
حقوق: http://onlinelibrary.wiley.com/termsAndConditions#vorTest
رقم الانضمام: edsbas.989BE7CC
قاعدة البيانات: BASE