دورية أكاديمية

Thorax artifacts in CT – Air embolism or other causes?

التفاصيل البيبلوغرافية
العنوان: Thorax artifacts in CT – Air embolism or other causes?
المؤلفون: Lavdas E., Papaioannou M., Tsikrika A., Pappas E., Sakkas G.K., Roka V., Kostopoulos S., Mavroidis P.
المصدر: International Journal of Radiation Research ; https://www.scopus.com/inward/record.uri?eid=2-s2.0-85117246291&doi=10.18869%2facadpub.ijrr.19.3.653&partnerID=40&md5=a08597769fee2a3503c2977306172217Test
سنة النشر: 2021
المجموعة: University of Thessaly Institutional Repository / Ιδρυματικό Αποθετήριο Πανεπιστημίου Θεσσαλίας
مصطلحات موضوعية: contrast medium, iodinated contrast medium, adult, aged, air embolism, aorta, aortic dissection, Article, artifact, ascending aorta, calcification, cardiac muscle, circulation, cohort analysis, computer assisted tomography, controlled study, diagnostic error, diagnostic test accuracy study, dyspnea, female, fever, follow up, hemoptysis, human, lung blood vessel, major clinical study, male, pneumonia, pulmonary vein, retrospective study
الوصف: Background: The existence of air in hollow organs in the thoracic cavity constitutes a life-threatening situation most of the times. However, sometimes in thoracic Computed Tomography (CT) there are artifacts from different sources that could mimic air densities, disorientating the diagnosis. Materials and Methods: 100 patients (46 females and 54 males, mean age: 60 years, range: 20-90 years), who had been routinely scanned in the area of thorax using three different imaging protocols (follow up, aorta, pulmonary vessels) were retrospectively studied. In 67 cases, contrast agent was used during the examination. Every case was studied by two specialists. Results: Artifacts in pulmonary veins were observed in 38 of the cases. Of these artifacts 27 stemmed from contrast agent, calcifications in the vessels, metallic implants, movement of the patient, malfunction of a detector due to the size of field of view (FOV) or due to the existence of contrast agent on the examination table of the CT scanner. In 11 cases, small amounts of air had been inserted into blood circulation during contrast injection. Conclusions: This study characterized and classified many artifacts related to thorax CT in order to separate them from other serious thoracic pathologies (e.g. aortic dissection, ulcer of veins or arteries). The knowledge and identification of the different types of artifacts is very important in order to avoid the risk of misdiagnosis. © 2021 Novin Medical Radiation Institute. All rights reserved.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 23223243
العلاقة: http://hdl.handle.net/11615/75717Test
DOI: 10.18869/acadpub.ijrr.19.3.653
الإتاحة: https://doi.org/10.18869/acadpub.ijrr.19.3.653Test
http://hdl.handle.net/11615/75717Test
رقم الانضمام: edsbas.86D6E012
قاعدة البيانات: BASE
الوصف
تدمد:23223243
DOI:10.18869/acadpub.ijrr.19.3.653