مؤتمر
Automated IMT estimation and BMI correlation using a low-quality carotid ultrasound image database from India.
العنوان: | Automated IMT estimation and BMI correlation using a low-quality carotid ultrasound image database from India. |
---|---|
المؤلفون: | MOLINARI, FILIPPO, MEIBURGER, KRISTEN MARIKO, Gupta V, Prabhakaran P, Saba L, Acharya UR, Ledda G, Krishna KV, Walia GK, Kinra S, Nicolaides A, Ebrahim S, Suri JS |
المساهمون: | Molinari, Filippo, Gupta, V, Prabhakaran, P, Meiburger, KRISTEN MARIKO, Saba, L, Acharya, Ur, Ledda, G, Krishna, Kv, Walia, Gk, Kinra, S, Nicolaides, A, Ebrahim, S, Suri, Js |
بيانات النشر: | USA IEEE / Institute of Electrical and Electronics Engineers Incorporated:445 Hoes Lane:Piscataway, NJ 08854:(800)701-4333, (732)981-0060, EMAIL: subscription-service@ieee.org, INTERNET: http://www.ieee.orgTest, Fax: (732)981-9667 |
سنة النشر: | 2013 |
المجموعة: | PORTO@iris (Publications Open Repository TOrino - Politecnico di Torino) |
مصطلحات موضوعية: | atherosclerosi, carotid, intima-media thickne, low-resolution, image segmentation, epidemiological study |
الوصف: | This paper presents AtheroEdgeLowRes (AELR), an extention of AtheroEdgeTM from AtheroPointTM, and a solution to carotid ultrasound IMT measurement in low-resolution and overall low quality images. The images were collected using a low-end ultrasound machine during a screening study in India. We aim to demonstrate the accuracy and reproducibility of the AELR system by benchmarking it against an expert Reader's manual tracing and to show the correlation between the automatically measured intima media thickness (IMT) and the subjects' cardiovascular risk factors (i.e. body mass index - BMI). We introduced an innovative penalty function (PF) to our dual-snake segmentation technique, necessary due to the low image resolution. We processed 512 images from 256 patients, and correlated the AELR IMT values with the patients' age and BMI. AELR processed all 512 images, and the IMT measurement error was 0.011±0.099 mm with the PF correction and 0.173±0.127 mm without. AELR IMT values correlated with the Reader's values (r = 0.883) and also correlated with the subject's BMI and age. The AELR system showed accuracy and reproducibility levels that make it suitable to be used in large epidemiological and screening studies in emerging countries. |
نوع الوثيقة: | conference object |
اللغة: | English |
العلاقة: | info:eu-repo/semantics/altIdentifier/wos/WOS:000341702103196; ispartofbook:Conference proceedings : . Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference; 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); volume:2013; firstpage:3343; lastpage:3346; numberofpages:4; journal:IEEE ENGINEERING IN MEDICINE AND BIOLOGY . ANNUAL CONFERENCE PROCEEDINGS; http://hdl.handle.net/11583/2517561Test; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84886558113; http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6610257Test |
DOI: | 10.1109/EMBC.2013.6610257 |
الإتاحة: | https://doi.org/10.1109/EMBC.2013.6610257Test http://hdl.handle.net/11583/2517561Test http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6610257Test |
حقوق: | info:eu-repo/semantics/openAccess |
رقم الانضمام: | edsbas.FC5C5E0F |
قاعدة البيانات: | BASE |
DOI: | 10.1109/EMBC.2013.6610257 |
---|