دورية أكاديمية

Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue

التفاصيل البيبلوغرافية
العنوان: Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue
المؤلفون: Mo, Zhong Jun, Bin Zhao, Yan, Wang, Li Zhen, Sun, Yu, Zhang, Ming, Fan, Yu Bo
المساهمون: Fan, YB (reprint author), Beihang Univ, Sch Biol Sci & Med Engn, Minist Sci & Technol, Int Joint Res Ctr Aerosp Biotechnol & Med Engn, XueYuan Rd 37, Beijing 100191, Peoples R China., Beihang Univ, Sch Biol Sci & Med Engn, Minist Sci & Technol, Int Joint Res Ctr Aerosp Biotechnol & Med Engn, Beijing 100191, Peoples R China., Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China., Peking Univ, Hosp 3, Dept Orthoped Surg, Beijing 100191, Peoples R China., Beihang Univ, Sch Biol Sci & Med Engn, Minist Sci & Technol, Int Joint Res Ctr Aerosp Biotechnol & Med Engn, XueYuan Rd 37, Beijing 100191, Peoples R China.
المصدر: SCI
بيانات النشر: european spine journal
سنة النشر: 2014
المجموعة: Peking University Institutional Repository (PKU IR) / 北京大学机构知识库
مصطلحات موضوعية: Cervical disc arthroplasty, U-shaped implant, Finite element method, Range of motion, Intradiscal pressure, Ligament strain, SPINE, FUSION, FLEXIBILITY, REPLACEMENT, DISKECTOMY, MODEL
الوصف: Various design concepts have been adopted in cervical disc prostheses, including sliding articulation and standalone configuration. This study aimed to evaluate the biomechanical effects of the standalone U-shaped configuration on the cervical spine. Based on an intact finite element model of C3-C7, a standalone U-shaped implant (DCI) was installed at C5-C6 and compared with a sliding articulation design (Prodisc-C) and an anterior fusion system. The range of motion (ROM), adjacent intradiscal pressure (IDP) and capsular ligament strain were calculated under different spinal motions. Compared to the intact configuration, the ROM at C5-C6 was reduced by 90 % after fusion, but increased by 70 % in the Prodisc-C model, while the maximum percentage change in the DCI model was 30 % decrease. At the adjacent segments, up to 32 % increase in ROM happened after fusion, while up to 34 % decrease occurred in Prodisc-C model and 17 % decrease in DCI model. The IDP increased by 11.6 % after fusion, but decreased by 5.6 and 6.3 % in the DCI and Prodisc-C model, respectively. The capsular ligament strain increased by 147 % in Prodisc-C and by 13 % in the DCI model. The DCI implant exhibited a high stress distribution. Spinal fusion resulted in compensatory increase of ROM at the adjacent sites, thereby elevating the IDP. Prodisc-C resulted in hyper-mobility at the operative site that led to an increase of ligament force and strain. The U-shaped implant could maintain the spinal kinematics and impose minimum influence on the adjacent soft tissues, despite the standalone configuration encountering the disadvantages of high stress distribution. ; Clinical Neurology ; Orthopedics ; SCI(E) ; 3 ; ARTICLE ; sunyuor@vip.sina.com; yubofan@buaa.edu.cn ; 3 ; 613-621 ; 23
نوع الوثيقة: journal/newspaper
اللغة: English
تدمد: 0940-6719
1432-0932
العلاقة: EUROPEAN SPINE JOURNAL.2014,23,(3),613-621.; 785896; http://hdl.handle.net/20.500.11897/215114Test; WOS:000332604600020
DOI: 10.1007/s00586-013-3070-4
الإتاحة: https://doi.org/20.500.11897/215114Test
https://doi.org/10.1007/s00586-013-3070-4Test
https://hdl.handle.net/20.500.11897/215114Test
رقم الانضمام: edsbas.2F22E51B
قاعدة البيانات: BASE
الوصف
تدمد:09406719
14320932
DOI:10.1007/s00586-013-3070-4