Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations: Microfluidics and Miniaturization

التفاصيل البيبلوغرافية
العنوان: Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations: Microfluidics and Miniaturization
المؤلفون: Meneses, Diogenes, Gunasekara, Dulan B., Pichetsurnthorn, Pann, da Silva, José A. F., de Abreu, Fabiane C., Lunte, Susan M.
المصدر: Scopus, 36(3)
سنة النشر: 2015
المجموعة: Carolina Digital Repository (UNC - University of North Carolina)
مصطلحات موضوعية: Dual-channel, Limit of Detection, Electrophoresis, Microchip, In-channel electrochemical detection, Equipment Design, Noise, Electrochemical Techniques, Electrically isolated potentiostat, Nitrites, Electrodes, Microchip electrophoresis, Microdialysis
الوصف: In-channel amperometric detection combined with dual-channel microchip electrophoresis is evaluated using a two-electrode isolated potentiostat for reverse polarity separations. The device consists of two separate channels with the working and reference electrodes placed at identical positions relative to the end of the channel, enabling noise subtraction. In previous reports of this configuration, normal polarity and a three-electrode detection system were used. In the two-electrode detection system described here, the electrode in the reference channel acts as both the counter and reference. The effect of electrode placement in the channels on noise and detector response was investigated using nitrite, tyrosine, and hydrogen peroxide as model compounds. The effects of electrode material and size and type of reference electrode on noise and the potential shift of hydrodynamic voltammograms for the model compounds were determined. In addition, the performance of two- and three-electrode configurations using Pt and Ag/AgCl reference electrodes was compared. Although the signal was attenuated with the Pt reference, the noise was also significantly reduced. It was found that lower LOD were obtained for all three compounds with the dual-channel configuration compared to single-channel, in-channel detection. The dual-channel method was then used for the detection of nitrite in a dermal microdialysis sample obtained from a sheep following nitroglycerin administration.
نوع الوثيقة: article in journal/newspaper
اللغة: English
العلاقة: https://doi.org/10.17615/4d6w-2431Test; https://cdr.lib.unc.edu/downloads/k643b888b?file=thumbnailTest; https://cdr.lib.unc.edu/downloads/k643b888bTest
DOI: 10.17615/4d6w-2431
الإتاحة: https://doi.org/10.17615/4d6w-2431Test
https://cdr.lib.unc.edu/downloads/k643b888b?file=thumbnailTest
https://cdr.lib.unc.edu/downloads/k643b888bTest
حقوق: http://rightsstatements.org/vocab/InC/1.0Test/
رقم الانضمام: edsbas.8C5EA9E6
قاعدة البيانات: BASE