دورية أكاديمية

Stent fracture as a complication of superficial femoral artery stenting – a case report

التفاصيل البيبلوغرافية
العنوان: Stent fracture as a complication of superficial femoral artery stenting – a case report
المؤلفون: Tkaczyk, Jędrzej, Terpiłowski, Michał, Brożyna, Klaudia, Baltaziak, Katarzyna, Klatka, Barbara, Kęsik, Jan Jakub, Iłżecki, Marek
المصدر: Journal of Education, Health and Sport; Tom 9 Nr 4 (2019); 293-300 ; Journal of Education, Health and Sport; Vol. 9 No. 4 (2019); 293-300 ; 2391-8306
بيانات النشر: Nicolaus Copernicus University, Toruń, Poland
سنة النشر: 2019
المجموعة: Akademicka Platforma Czasopism
مصطلحات موضوعية: stent fracture, superficial femoral artery stenting, vascular surgery
الوصف: Introduction: Peripheral artery disease (PAD) is an atherosclerotic vascular disease that results in obstruction of blood flow in the arteries other than those in the coronary circulation. PAD is often located in lower extremities, with patients presenting symptoms of intermittent claudication or critical lower limb ischemia. Angioplasty and stent implantation are often used in the treatment of PAD. Although these methods are considered as a low invasive and low risk, some factors may limit stent patency in the future. The fracture of the implanted stent may be one of these. Case report: A 68 old man, long-term smoker, with a history of chronic limb ischemia and many vascular surgeries because of PAD was admitted to the hospital with symptoms of the acute limb ischemia. Angiography showed a fracture of the stent implanted during the earlier hospitalization, with a fragment displacement to the left external iliac artery. The patient was successfully treated with catheter-directed thrombolysis. Discussion: Stent fracture is usually asymptomatic, however, it may cause complications, such as restenosis, pseudoaneurysm, perforation of the vessel, and in-stent embolism. The cumulative incidence of the femoropopliteal stent fracture varies from 2 to 65% in several studies. Incidence increases with stent length and is significantly lower in the second generation of nitinol stents, that was designed to have enhanced flexibility and durability.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
العلاقة: https://apcz.umk.pl/JEHS/article/view/6807/pdfTest; https://apcz.umk.pl/JEHS/article/view/6807Test
الإتاحة: https://apcz.umk.pl/JEHS/article/view/6807Test
حقوق: Prawa autorskie (c) 2019 © The Author(s)
رقم الانضمام: edsbas.9B1A19D3
قاعدة البيانات: BASE