دورية أكاديمية

Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital

التفاصيل البيبلوغرافية
العنوان: Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital
المؤلفون: Aseem K Tiwari, Prashant K Pandey, Ravi C Dara, Ganesh S Rawat, Vimarsh Raina, Richa Bhargava
المصدر: Asian Journal of Transfusion Science, Vol 9, Iss 1, Pp 65-69 (2015)
بيانات النشر: Wolters Kluwer Medknow Publications, 2015.
سنة النشر: 2015
المجموعة: LCC:Diseases of the blood and blood-forming organs
مصطلحات موضوعية: Non-treponemal test, serological test for syphilis, treponemal test, Diseases of the blood and blood-forming organs, RC633-647.5
الوصف: Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0973-6247
1998-3565
العلاقة: http://www.ajts.org/article.asp?issn=0973-6247;year=2015;volume=9;issue=1;spage=65;epage=69;aulast=TiwariTest; https://doaj.org/toc/0973-6247Test; https://doaj.org/toc/1998-3565Test
DOI: 10.4103/0973-6247.150955
الوصول الحر: https://doaj.org/article/3ae8a3df361c4791bdea0f70808971efTest
رقم الانضمام: edsdoj.3ae8a3df361c4791bdea0f70808971ef
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09736247
19983565
DOI:10.4103/0973-6247.150955