دورية أكاديمية

Effects of Different Degrees of Extraluminal Compression on Hemodynamics in a Prominent Transverse-Sigmoid Sinus Junction

التفاصيل البيبلوغرافية
العنوان: Effects of Different Degrees of Extraluminal Compression on Hemodynamics in a Prominent Transverse-Sigmoid Sinus Junction
المؤلفون: Xiaoyu Qiu, Pengfei Zhao, Zhenxia Mu, Chihang Dai, Xiaoshuai Li, Ning Xu, Heyu Ding, Shusheng Gong, Zhenghan Yang, Bin Gao, Zhenchang Wang
المصدر: Frontiers in Human Neuroscience, Vol 16 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: pulsatile tinnitus, cranial venous sinuses, compression degree, computational fluid dynamics (CFD), hemodynamics, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: ObjectivesTo simulate hemodynamic changes after extraluminal compression in pulsatile tinnitus (PT) patients with a prominent transverse-sigmoid sinus junction (PTSJ).MethodsOne patient-specific case was reconstructed based on computed tomography venography (CTV) images of a PT patient. The compression degree served as a new index in this study. Cases with 10, 20, 30, 40, 50, 60, 70, 80, and 90% of the compression degree of the control subject were constructed. Steady-state computational fluid dynamics (CFD) were assessed. The wall pressure distribution, wall maximum pressure (Pmax) and flow pattern (velocity streamlines and velocity vector) of the PTSJ were calculated to evaluate hemodynamic differences among all cases.ResultsWith increasing compression, the wall pressure at the compression point and downstream of the PTSJ decreased but increased upstream. When the compression degree exceeded 70%, the upstream pressure increased significantly. Above 50% compression, the blood flow pattern downstream of the sigmoid sinus tended to spiral, especially after 80% compression. Beyond 60% compression, the blood flow pattern under the compression axis became more medial.ConclusionMechanical compression of PTSJ changes wall pressure and blood flow patterns. The degree of compression should be carefully observed to avoid possible complications or reoccurrence.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1662-5161
العلاقة: https://www.frontiersin.org/articles/10.3389/fnhum.2022.823455/fullTest; https://doaj.org/toc/1662-5161Test
DOI: 10.3389/fnhum.2022.823455
الوصول الحر: https://doaj.org/article/93f5453d26cf432e9d503f3dc33bbb6bTest
رقم الانضمام: edsdoj.93f5453d26cf432e9d503f3dc33bbb6b
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16625161
DOI:10.3389/fnhum.2022.823455